💻 IT setup and notes#

This page contains the information for the IT team.

Schematic for the Carnival IT setup#

Technical notes#

Network setup#

Router NETGEAR AC1200

  • IP 192.168.0.1

  • user admin

  • pass 1111

  • WiFi is disabled

Access point

  • To be fixed to the tent pole

  • Power over Ethernet (PoE) injector with power adapter

  • DHCP assigned IP

  • SSID MTBO

  • WPA2-PSK I<3mtbo!

Computers setup#

SPRINT “Download server” laptop

  • Fixed IP 192.168.0.10

  • MeOS in network mode

  • MySQL database

    • Address: 192.168.0.10:3306

    • pass OACT

  • Competition information is stored in MySQL database

  • Results export + oScreen scripts for display

  • oScreen parser-and-server (see setup below)

  • serial monitor for meshO diagnostics log (see setup below)

TODO: Upload competition to the MySQL database

OACT21 “Enquiries” laptop

  • MeOS in network mode

  • Connect to MySQL database on the SPRINT “Download server” laptop

  • Online results (see setup below)

OACT22 “Backup download” laptop

  • Independent stand-alone MeOS instance

MTBO Acer Spin laptop

  • MeOS in network mode

  • Connect to MySQL database on the SPRINT “Download server” laptop

  • Announcer screen in MeOS

oScreen setup#

TODO: Add setup instructions for the server

Setup on the screens:

  • URL: http://192.168.0.10:5000?kiosk_id=NNN

Online results#

Online results are to be set up on OACT21 “Enquiries” laptop.

  • Start Online Results service in MeOS

  • Run every 15 sec

  • Dropdown: MeOS Online Protocol XML 2.0

  • Check Compress large files and Send to the web URL and nothing else

  • Fill out competition ID and Password

  • URL https://www.melin.nu/online/emma/emmaupdate.php

  • Competition IDs:

    • Warm-up: 31547

    • Mass: 31548

    • Sprint: 31550

    • Middle: 31549

    • Long: 31551

  • Password: I<3mtbo

meshO diagnostics setup#

  • Radio meshO Prime unit is to be connected to the SPRINT “Download server” laptop

  • The unit provides two COM interfaces:

    1. For MeOS punch import, appears as SI dongle

    2. For diagnostics log, VS Code serial monitor can be used to monitor the log

  • In addition, a separate meshO Diagnostics unit can be connected to a separate laptop where Digi XCTU software can be used to diagnose the mesh network

  • Tate will run these diagnostics

Rented SI-Air sticks numbers#

From Orienteering ACT

8581175 8581176 8581177 8581178 8581179 8581180 8581181 8581182 8581183 8581184 8581185 8581186 8581187 8581188 8581189 8581190 8581191 8581192 8581193 8581194 8625439 8633229 8635973 8635984 8636015 8636023 8643872 8643888 8643903 8643912 8652477 8652481 8652483

csv file

From Orienteering Australia

8237655 8237674 8237688 8516219 8516246

csv file

From Craig Steffens

8510855 8510856 8510857 8510858 8510859 8510860 8510861 8510862 8510863 8511702 8511703 8511705 8511706 8511715 8512539 8512543 8512545 8512546 8512547 8512549

csv file

From Colin Price

8627351 8635903 8635904 8635907 8635933 8635936 8635945 8635948 8635950 8635951 8635957 8635958 8635959 8635965 8635966 8635975 8635993 8635996 8636014 8636020 8636022 8636027 8636032 8636036 8636038 8636039 8636042 8636045 8636047 8636567 8639403 8639405 8639407 8639414 8639416 8639417 8639418 8639420 8639421 8639423 8639425 8639426 8639430 8639432 8639433 8639436 8639439 8639440 8639441 8639442 8639446 8639448 8639449 8652453

csv file